Blast Resistant Shelters

Keeping your number one asset – your workforce – safe and secure on hazardous work sites while still meeting your production goals can be a challenge. You need your people as close to the site as possible to maximize wrench time, increase productivity, and save costs, all the while ensuring their protection.

A highly specialized blast resistant air shelter from Dynamic Air Shelters can protect your workforce and deliver greater value than conventional alternatives such as modular containers or tent structures. Engineered with fail safe and safe fail features, Dynamic Air Shelters are built for optimum protection and security in blast zone environments. Our blast resistant air shelters qualify for and are widely used in Zone 1 and 2 siting locations for refineries and chemical plants. Dynamic’s shelters are suitable for API RP 756 -recommended guidelines adopted by the American Petroleum Institute.

Our blast resistant shelters stand up to the test

Blast testing demonstrated the ability of blast resistant shelters to remain secure and reduce injury even in the most lethal environments. Dynamic Air Shelters have been tested and proven to:

Stand up to shock loads as high as 11.5 psi for a duration of more than 66 ms – in general, the larger the blast, the more the effects of the blast are mitigated by the shelter Deflect the force of shock-waves up rather than horizontally

– away from people, objects and congested areas

Offer protection from debris at various levels, including options for protection from military threats

Dampen harmful incident waves and reduce shock-waves to less dangerous compression waves

– No secondary reflective wave is created inside the structure

Additional safety features

Fire-retardant to meet NFPA 701 (USA) and ULC S109 (Canada) codes Weather-resistant to withstand sustained wind speeds to 95 mph (152 km/h) Some models certified to withstand up to Category 3 hurricane sustained wind speeds at 130 mph (209 km/h) Certifiable to remain secure under elevated snow load conditions Suitable for use as shelter-in-place protection from H2S Engineering audits completed by the world’s leading petro chemical companies and their representatives confirm that Dynamic Air Shelters are suitable for API RP 756 guidelines 

Impermeable to toxic gases Suitable in temperatures from -60° to 158°F (-50° to 70°C) All lights are shatterproof and secured without the need for rigid components ,Flexible tether masts allow for enhanced blast-resistance In the unlikely event of a structural failure during an incident, the structure will yield articles of low mass moving at very low velocity, which would result in extremely low probabilities of injury.

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

 

Inspection and re-certification of our blast resistant shelters

Maintaining the integrity of our blast resistant shelters is a top priority for Dynamic Air Shelters. We will conduct a full inspection of your shelter on a regular basis to ensure that it can withstand a blast and protect its occupants. In harsh environments, we recommend an inspection and re-certification once a year.

The inspection process consists of:

Taking a sample of the outer cover, or fly, and analyzing the strength of the material in remote laboratory tests A thorough inspection of all soft components including the outer fly, the inner curtain, HVAC plenum, and air beam columns A thorough inspection of all hardware including doors, floors, anchoring points, tethering systems, and cable system Any deficiencies found during the inspection will be corrected on site if possible, or new parts will be ordered promptly and shipped to the site. Once any deficiencies are corrected, and a positive laboratory test for the fly is received, Dynamic Air Shelters will issue a re-certification letter for your shelter.

Bottom-line benefits of blast resistant air shelters

by Dynamic Air Shelters Injuries and fatalities caused by fuel air explosions on the work site have dictated the need to move common area structures further from lethal environments. But relocating these facilities increases project costs and time. Travel time to and from the site, and the logistics of housing a large workforce in multiple buildings away from the plant site has a negative effect on project efficiency. Dynamic Air Shelters allow you to move your workers closer to the work site, achieving significant savings on labor costs due to having your personnel at or near the work site, eliminating or reducing travel time.

More cost savings realized:

Installation costs are as much as 85 percent less than conventional temporary hard- and soft-walled structures and as much as 98 percent less than permanent buildings Thermal efficient design offers reduced heating costs compared to traditional soft-walled structures Larger space means cost-per-square-foot savings Lightweight portability decreases transportation costs Designed to fit in anywhere blast shelters are required Dynamic Air Shelters blast resistant buildings are easy to transport and can be rapidly set up and just as easily demobilized virtually anywhere. Available for purchase for long-term assignments, or to rent for short-term use Over 14 standard sizes available – from 13 ft. x 23 ft. to 78 ft. x 208 ft. (300 to 16,000 sq. ft.) Custom sizes and configurations are available for all your needs

Easily and rapidly set up by a small team without the use of cranes or lifting equipment – 100% turnkey installations available or a Dynamic Air Shelter installation expert can guide your own personnel through setup and dismantling. Learn more about our Field Operations. Lightweight structures can be moved a short distance on site while fully deployed Compact packaging for easier storage and transportation – 9,000 sq. ft. structure is transported in three 20 ft. shipping containers Can include electrical, lighting, HVAC, insulation and air filtration systems Large, clear spans optimize the space/occupancy ratios allowing room for hundreds of people Dynamic Air Shelters are tested and proven to keep your at-risk workforce safe and out of harm’s way within threatened areas of work sites. Read more about API RP 756 standards, or contact us to discuss your unique requirements for blast shelters.

Military Shelters

PROTECTION AGAINST THE DEADLY THREAT OF BLAST AND BALLISTIC HAZARDS

The new face of war involves IEDs and other blast and ballistic weaponry, creating a heightened need for blast protection for military forces. Dynamic Air Shelters are ideal for use in war zones as large, industrial-sized, rapidly deployable shelters for hangars, camps and machine shop warehouses. Designed to defend against a serious explosive threat and able to withstand high velocity impact, Dynamic Air Shelters have been successfully tested in full-scale field trials at the Canadian Defence Research and Development Centre. They offer protection and shelter unlike any other solution in the industry today. Inflatable air shelters cushion the blow The Dynamic Air Shelters’ system is comprised of a low-pressure air beam support structure, a heavy-duty waterproof fabric shell and liner, and a flexible moveable exterior fabric barrier surrounding the perimeter. A geotextile support wall protects against ballistic threats. In testing, the shelter has consistently reduced the amplitude and severity of a shock wave thanks to its ability to reduce the rise time of a shock wave by as much as one thousand-fold, and reduce a shock wave to a compression wave. Generally, the larger the blast, the better the shelter mitigates the effects. The shelter can withstand punctures or ruptures. In the event of catastrophic rupture the shelter will deflate in a fashion that does not cause injury to its occupants.

Optimal safety

Where the force of a blast can easily shatter permanent structures, the inflated pillars of Dynamic’s air shelters will simply absorb and deflect the impact. In addition to the blast- and ballistic-resistant properties, the shelters are fire-resistant, constructed from materials that meet international standards (NFPA 701 USA and ULC S109 Canada). The new face of war involves IEDs and other blast and ballistic weaponry, creating a heightened need for blast protection for military forces. Dynamic Air Shelters are ideal for use in war zones as large, industrial-sized, rapidly deployable shelters for hangars, camps and machine shop warehouses. Designed to defend against a serious explosive threat and able to withstand high velocity impact, Dynamic Air Shelters have been successfully tested in full-scale field trials at the Canadian Defence Research and Development Centre. They offer protection and shelter unlike any other solution in the industry today.